IBM DS Storage Manager 윈도우용 다운로드

 

 

설치가능 OS

 

  • Windows Server 2003 32bit
  • Windows Server 2008 32bit
  •  

     

    출시일자 : 2008-10-08

    버전 : 10.30

     

     

    다운로드 : 클릭

     

     

     

    상세 설명서

    IBM System Storage™ DS Storage Manager version 10.30.xx.09 for 
    Microsoft Windows Server 2008 - x86 and Windows Server 2003 SP2 - x86 (32bit) 
    operating system environments.
    
    NOTE TO SERVICE – Reference RETAIN # N/A
    
    (C) Copyright International Business Machines Corporation 1999, 2008. All 
    rights reserved. US Government Users Restricted Rights - Use, duplication, 
    or disclosure restricted by GSA ADP Schedule Contract with IBM Corp.
    
    Note: Before using this information and the product it supports, read the 
    general information in section 6.0 "Trademarks and Notices" in this document.
    
    Last Update:   08/15/2008
    Please refer to corresponding Change History document for more information 
    on new features and modifications.
    
    
    IMPORTANT: 
    
    1. DS4000 Storage Manager version 9.19.xx.12 and later is required for
       DS4000 storage subsystem users in countries implementing the new 
       Daylight Saving Time (DST) rules (which includes U.S., Canada, 
       Bermuda). Storage Manager version 9.19.xx.12 or later release includes 
       revised DST transition dates to comply with provision of the Energy 
       Policy Act of 2005 extension of Daylight Saving Time (DST) by 
       four weeks, beginning in year 2007. 
       Please refer to section 1.3 Enhancements for more information. 
    
    2. Microsoft Windows host attachment to the DS4200, DS4700, DS4800, DS5100 
       or DS5300 storage subsystems requires the additional purchase of the IBM 
       DS4000/DS5000 Microsoft Windows operating system Host Kit Option or 
       Feature Code. The IBM DS4000/DS5000 Microsoft Windows Host Kit options 
       contain the required IBM licensing to attach an Microsoft Windows Host 
       System to the DS4200, DS4700, DS4800, DS5100 or DS5300. Please contact 
       your IBM service representative or IBM reseller for purchasing 
       information. This host kit is shipped as standard in the DS4200 storage 
       subsystem models 7VH, DS4700 storage subsystem models 70H, 70T, 72H and 
       72T and the DS4800 storage subsystem models 80H, 82H, 84H and 88H. 
    
    3. The Microsoft Windows NT4 and Windows 2000 is not supported with this version 
       of the IBM System Storage™ DS Storage Manager. In addition, the only 
       DS4000/DS5000 Storage Manager host software support on Microsoft Windows 
       XP Professional and Microsoft Windows Vista operating systems is the DS 
       Storage Manager client program.
    
    4. Review section 3.2 "Hardware status and information" for the list of
       recommended fibre channel host bus adapters and their driver versions.
    
    
    Refer to the IBM System Storage™ Support Web Site or CD for the IBM System 
    Storage DS Storage Manager Version 10 Installation and Host Support Guide.
    This guide along with the DS Storage Manager program Online Help provide 
    the installation and support information. 
    
    
    Products Supported   
    
        ----------------------------------------------------------------
       | New Model  | Old Model | Machine Type |     Model              |
       |------------|-----------|--------------|------------------------|
       |  DS5300    |   N/A     |     1818     | 53A                    |
       |------------|-----------|--------------|------------------------|
       |  DS5100    |   N/A     |     1818     | 51A                    |
       |------------|-----------|--------------|------------------------|   
       |  DS4800    |   N/A     |     1815     | 82A, 82H, 84A, 84H,    |
       |            |           |              | 88A, 88H, 80A, 80H     |
       |------------|-----------|--------------|------------------------|
       |  DS4700    |   N/A     |     1814     | 70A, 70H, 72A, 72H,    |
       |            |           |              | 70T, 70S, 72T, 72S,    |
       |------------|-----------|--------------|------------------------|
       |  DS4500    | FAStT 900 |     1742     | 90X, 90U               |
       |------------|-----------|--------------|------------------------|
       |  DS4400    | FAStT 700 |     1742     | 1RX, 1RU               |
       |------------|-----------|--------------|------------------------|
       |  DS4300    | FAStT 600 |     1722     | 60X, 60U, 60J, 60K,    |
       |            |           |              | 60L                    |
       |------------|-----------|--------------|------------------------|
       |  DS4200    |   N/A     |     1814     | 7VA, 7VH               |
       |----------- |-----------|--------------|------------------------|
       |  DS4100    | FAStT 100 |     1724     | 100, 1SC               |
       |----------- |-----------|--------------|------------------------|
       |  DS3400    |   N/A     |     1726     | 41X, 42X, HC4          |
       |----------- |-----------|--------------|------------------------|
       |  DS3300    |   N/A     |     1726     | 31X, 32X, 31E, 32E     |
       |----------- |-----------|--------------|------------------------|
       |  DS3200    |   N/A     |     1726     | 21X, 22X, HC2          |
        ------------ ---------------------------------------------------
    
    ATTENTION:
      1. The DS4000 storage subsystem controller firmware version 05.40.xx.xx 
         and earlier along with its associated NVSRAM files should not be loaded 
         into DS4000 storage subsystems connected to DS4000 EXP100 drive 
         expansion enclosures. 
      2. For the DS4400 and the DS4100 storage subsystems - all models (Standard
         /dual controller and Single Controller), the controller firmware version 
         06.12.xx.xx and later must be used.
      3. For the DS4300 storage subsystems with Single Controller option, the 
         controller firmware version 05.34.xx.xx and its associated NVSRAM file 
         must be used. Do not attempt to download the controller firmware version 
         06.xx.xx.xx into these DS4300 storage subsystem models with single 
         controller option.                           
      4. For the FAStT200 (M/T 3542-all models) and FAStT500 (M/T 3552-all models)
         storage subsystems, the controller firmware version 05.30.xx.xx and its 
         associated NVSRAM file must be used. Do not attempt to download the 
         controller firmware version 06.xx.xx.xx into these DS4000 storage 
         subsystems.
      5. For the DS4300 with Standard (base) or Turbo options and the DS4500 
         storage subsystems connected to the DS4000 EXP810 drive expansion 
         enclosures, the latest controller firmware version 06.23.xx.xx (and 
         higher) and its associated NVSRAM file must be used. It is also 
         recommended that the DS4300 with Standard (base) or Turbo options and 
         the DS4500 storage subsystems be upgraded to this controller firmware 
         version even though they are not planned to have DS4000 EXP810 drive 
         expansion enclosure attachment.    
      6. For the DS4700 and the DS4800 storage subsystems connected to the DS4000
         EXP100 drive expansion enclosures, the controller firmware version 
         06.23.xx.xx (and higher) and its associated NVSRAM file must be used. It 
         is also recommended that the DS4700 and the DS4800 storage subsystems be 
         upgraded to this controller firmware version even though they are not 
         planned to have DS4000 EXP100 drive expansion enclosure attachment.    
      7. For the DS3x00 storage subsystems, please refer to the readme files that
         are posted in the IBM DS3000 System Storage support web site for the 
         latest information about their usage, limitations or configurations. 
         http://www.ibm.com/servers/storage/support/
      8. For Host I/O attach, DS Storage Manager Installer (SMIA) package 
         version 10.30.xx.xx for Microsoft Windows Server 2008 and Microsoft 
         Windows Server 2003 SP2 editions, requires DS4000/DS5000 Controller 
         firmware version 06.12.xx.xx or later.    
     
     
    CONTENTS
    --------
    1.0   Overview
    2.0   Installation and Setup Instructions
    3.0   Configuration Information
    4.0   Unattended Mode
    5.0   Web Sites and Support Phone Number
    6.0   Trademarks and Notices
    7.0   Disclaimer
    
    =======================================================================
    
    1.0   Overview
    --------------
    
    1.1  Overview
    --------------
    
       This is the initial release of the IBM DS Storage Manager 10.30 for 
       Microsoft Windows Server 2008 and Microsoft Windows Server 2003 SP2 
       operating system environments. This version 10.30 of the DS Storage 
       Manager host software is required for managing the DS5300-all models and 
       the DS5100-all models with controller firmware version 07.30.xx.xx. In 
       addition, it is also recommended for managing the following DS4000 
       storage subsystems - the DS4100-all models, DS4200-all models, DS4300-
       all models, the DS4400-all models, the DS4500-all models, DS4700-all 
       models, and the DS4800-all models with controller firmware version 
       05.34.xx.xx or higher installed.
       NOTE: 
        DS4000 controller firmware versions 6.12.xx.xx
         * Attachment support for EXP710 and EXP100 SATA disk drive 
           expansion enclosures.
         * No attachment support for EXP810 disk drive expansion enclosure.    
         
         DS4000 controller firmware version 06.60.xx.xx  
         * Attachment support for EXP710, EXP810, and EXP100 SATA disk drive 
           expansion enclosures for DS4300 with dual controller, DS4500, DS4700 
           and DS4800.
         * Attachment support for EXP420 for DS4200 only.
    
         DS4000 controller firmware version 7.15.xx.xx
         *  Supports DS4200, DS4700, and DS4800 only.
         
         DS5000 controller firmware version 7.30.xx.xx
         *  Supports DS5100 and DS5300 only.     
     
       The IBM Storage Manager host software version 10.30 new features and 
       changes are described in the corresponding Change History document. 
       Please refer to this document for more information on new features and 
       modifications.
      
       Notes:
       
       1. There are separate IBM DS Storage Manager host software version 10.30 
          packages for the following Microsoft Windows Server 2003-x86, Windows 
          Server 2008-x86; Windows Server 2003 Intel Architecture Itanium 64bit 
          (IA-64); and Windows Server 2008-x64, and Windows Server 2003-X64 
          64bit (AMD64 and EM64T). The WS03_WS08_X86, WS03_IA64, and 
          WS03_WS08_X64 CD directories contain the files necessary for 
          installing the IBM DS Storage Manager Version 10.30 host software in 
          the Windows Server 2003 - x86, Windows Server 2008 - x86, Windows 
          Server 2003 Intel Itanium2 64bit, Windows Server 2003 x64 and Windows 
          Server 2008 x64 64bit (AMD64 and EM64T) Operating System (OS) 
          environments, respectively. Please select the appropriate directory 
          for your operating system environment. The host software and 
          DS4000/DS5000 storage subsystem firmware files are packaged 
          separately and are available for download from the IBM System 
          Storage™ Disk Storage Systems Technical Support web site: 
          http://www.ibm.com/servers/storage/support/disk/
       
       2. This version of DS Storage Manager host software does not support 
          Microsoft Windows NT4 and Windows 2000 Operating System. In addition, 
          the only DS Storage Manager host software support on Windows XP 
          Professional OS and Windows Vista is the DS Storage Manager client 
          (SMClient) program from the IBM DS Storage Manager host software 
          package for Microsoft Windows Server 2008 - x86 (32bit).
          
        
       The IBM System Storage DS Storage Manager Version 10 Installation 
       and Host Support Guide is also available on IBM's Support Web Site as a 
       downloadable Portable Document Format (PDF) file. It contains the 
       instructions for installing the IBM DS Storage Manager version 10.30 
       host software. 
     
       Not all versions of Microsoft Windows operating systems are IO-attach 
       support for each of the DS4000/DS5000 storage subsystem model. 
       
       Windows Operating Systems Supported   
       ------------------------------------
        -----------------------------------------------------------
       |      DS4000       |Windows Server 2003/2008| Server 2003  |
       | Storage Subsystem |  32bit | 64bit - X64   | 64bit - IA64 | 
       |-------------------|--------|---------------|--------------|
       |  DS5300           |  Yes   |  Yes          |  Yes         |
       |-------------------|--------|---------------|--------------|
       |  DS5100           |  Yes   |  Yes          |  Yes         |
       |-------------------|--------|---------------|--------------|   
       |  DS4800           |  Yes   |  Yes          |  Yes         |
       |-------------------|--------|---------------|--------------|
       |  DS4700           |  Yes   |  Yes          |  Yes         |
       |-------------------|--------|---------------|--------------|
       |  DS4500           |  Yes   |  Yes          |  Yes         |
       |-------------------|--------|---------------|--------------|
       |  DS4400           |  Yes   |  Yes          |  Yes         |
       |-------------------|--------|---------------|--------------|
       |  DS4300           |  Yes   |  Yes          |  Yes         |
       |-------------------|--------|---------------|--------------|
       |  DS4200           |  Yes   |  Yes          |  Yes         |
       |-------------------|--------|---------------|--------------|
       |  DS4100           |  Yes   |  Yes          |  Yes         |
       |-------------------|--------|---------------|--------------|
       |  FAStT500         |  No    |  No           |  No          |
       |-------------------|--------|---------------|--------------|
       |  FAStT200         |  No    |  No           |  No          |
        ------------------------------------------------------------
       Note: Only the DS4300 with Standard (base) or Turbo options are supported
       for I/O attach with this release of DS Storage Manager Host Software
       for Windows.
    
    
    
       IMPORTANT: This release of IBM DS Storage Manager host software Client, 
       supports managing all DS4000/DS5000 storage subsystems with general 
       released firmware versions from 05.30.xx.xx up to 07.30.xx.xx and the 
       DS3200, DS3400 and DS3300 storage subsytems with controller firmware 
       version 06.70.xx.xx, or earlier, installed.   
       
       Refer to the IBM Support Web Site for latest DS4000/DS5000 controller 
       firmware and NVSRAM files for IBM machine types 1722, 1724, 1742, 1814, 
       1815, 1818, 3542 and 3552. The following table shows the first four 
       digits of the latest controller firmware versions that are currently 
       available for various models of the DS4000/DS5000 storage subsystems.
       
             ---------------------------------------------------
            | DS4000 Storage   |  Controller firmware version   |
            | Subsystem Model  |                                |
            |------------------|--------------------------------|
            | DS5300 (1818)    | 07.30.xx.xx                    |    
            |------------------|--------------------------------|            
            | DS5100 (1818)    | 07.30.xx.xx                    |        
            |------------------|--------------------------------|
            | DS4800 (1815)    | 07.15.xx.xx                    |
            |                  |                                |
            |------------------|--------------------------------|
            | DS4700 (1814)    | 07.15.xx.xx                    |
            |------------------|--------------------------------|
            | DS4500 (1742)    | 06.60.xx.xx                    |
            |------------------|--------------------------------|
            | DS4400 (1742)    | 06.12.56.xx                    |
            |------------------|--------------------------------|
            | DS4300 Turbo     | 06.60.xx.xx                    |
            | Option (1722)    |                                |
            |------------------|--------------------------------|
            | DS4300           | 06.60.xx.xx                    |
            | Standard Option  |                                |
            | (1722)           |                                |
            |------------------|--------------------------------|
            | DS4300 Single    | 05.34.xx.xx                    |
            | Controller Opt.  | (for DS4300 SCU                |
            | (SCU)(1722)      |  only)                         |
            |------------------|--------------------------------|
            | DS4200 (1814)    | 07.15.xx.xx                    |
            |------------------|--------------------------------|
            | DS4100 (1724)    | 06.12.56.xx                    |
            | (standard dual   |                                |
            |  Single          |                                |
            |  controller Opt.)|                                |
            |------------------|--------------------------------|
            | FAStT500 (3552)  | 05.30.xx.xx                    |
            |------------------|--------------------------------|
            | FAStT200 (3542)  | 05.30.xx.xx                    |
             ---------------------------------------------------
            Note: 
            1. Controller firmware 06.23.xx.xx or higher is required for the 
            DS4300-standard- dual controller or Turbo models, the DS4500-all 
            models, the DS4700- all models and the DS4800-all models for 
            attaching combinations of EXP810 and EXP100 storage expansion 
            enclosures behind a DS4000 storage subsystem.
            
            2. Controller firmware version 06.12.xx.xx or higher is required
            for Host I/O attach with this release of DS Storage Manager 
            for Windows.
    
       For the DS3x00 storage subsystems, please refer to the readme files that 
       are posted in the IBM DS3000 System Storage support web site for the 
       latest information about theirs usage, limitations or configurations. 
       http://www.ibm.com/servers/storage/support/
    
       New features that are introduced with the controller firmware version 
       07.30.xx.xx or later will not be available for any DS5000/DS4000 storage 
       subsystem controllers without the controller firmware version 
       07.30.xx.xx or later installed.
    
       The following table shows the controller firmware versions required for
       attaching the various models of the DS4000/DS5000 Storage Expansion Enclosures.
       
       ------------------------------------------------------------------------------
       | Controller |           EXP Storage Expansion Enclosures                    |
       | FW Version |---------------------------------------------------------------|
       |            | EXP100 | EXP420 | EXP500 | EXP700 | EXP710 | EXP810 | EXP5000 |
       |------------|--------|--------|--------|--------|--------|--------|---------|
       |5.3x.xx.xx  |   No   |   No   |  Yes   |  Yes   |   No   |   No   |   No    |
       |------------|--------|--------|--------|--------|--------|--------|---------|
       |5.40.xx.xx  |   No   |   No   |  Yes   |  Yes   |   No   |   No   |   No    |
       |------------|--------|--------|--------|--------|--------|--------|---------|
       |5.41.xx.xx  |  Yes   |   No   |   No   |   No   |   No   |   No   |   No    |
       |------------|--------|--------|--------|--------|--------|--------|---------|
       |5.42.xx.xx  |  Yes   |   No   |   No   |   No   |   No   |   No   |   No    |
       |------------|--------|--------|--------|--------|--------|--------|---------|
       |6.10.0x.xx  |  Yes   |   No   |   Yes  |  Yes   |   No   |   No   |   No    |
       |------------|--------|--------|--------|--------|--------|--------|---------|
       |6.10.1x.xx  |  Yes   |   No   |   Yes  |  Yes   |  Yes   |   No   |   No    |
       |------------|--------|--------|--------|--------|--------|--------|---------|
       |6.12.xx.xx  |  Yes   |   No   |   Yes  |  Yes   |  Yes   |   No   |   No    |
       |------------|--------|--------|--------|--------|--------|--------|---------|
       |6.14.xx.xx  |  Yes   |   No   |   No   |   No   |  Yes   |   No   |   No    |
       |------------|--------|--------|--------|--------|--------|--------|---------|
       |6.15.xx.xx  |  Yes   |   No   |   No   |   No   |  Yes   |   No   |   No    |
       |------------|--------|--------|--------|--------|--------|--------|---------|
       |6.16.2x.xx  |   No   |   No   |   No   |   No   |  Yes   |  Yes   |   No    |
       |------------|--------|--------|--------|--------|--------|--------|---------|
       |6.16.8x.xx  |   No   |  Yes   |   No   |   No   |  Yes   |  Yes   |   No    |
       |------------|--------|--------|--------|--------|--------|--------|---------|
       |6.16.9x.xx  |   No   |  Yes   |   No   |   No   |  Yes   |  Yes   |   No    |
       |------------|--------|--------|--------|--------|--------|--------|---------|
       |6.19.xx.xx  |  Yes   |   No   |   No   |   No   |  Yes   |  Yes   |   No    |
       |------------|--------|--------|--------|--------|--------|--------|---------|
       |6.23.xx.xx  |  Yes   |  Yes   |   No   |   No   |  Yes   |  Yes   |   No    |
       |------------|--------|--------|--------|--------|--------|--------|---------|
       |6.60.xx.xx  |  Yes   |  Yes   |   No   |   No   |  Yes   |  Yes   |   No    |   
       |------------|--------|--------|--------|--------|--------|--------|---------|
       |7.10.xx.xx  |  Yes   |  Yes   |   No   |   No   |  Yes   |  Yes   |   No    |   
       |------------|--------|--------|--------|--------|--------|--------|---------|
       |7.15.xx.xx  |  Yes   |  Yes   |   No   |   No   |  Yes   |  Yes   |   No    |   
       |------------|--------|--------|--------|--------|--------|--------|---------|
       |7.30.xx.xx  |   No   |   No   |   No   |   No   |   No   |  Yes   |   Yes   |   
       ------------------------------------------------------------------------------
       Note: EXP500 and EXP710/EXP100 can not be attached behind the same DS4000 
       storage subsystem. In addition, the EXP500 can only be intermixed with 
       EXP700 if the fibre channel speed of the EXP700 and the DS4000 subsystem 
       drive loop is set to 1Gbps. 
    =======================================================================
    
    1.2  Limitations
    ----------------
    IMPORTANT:
    The listed limitations are cumulative. However, they are listed by the 
    DS4000/DS5000 storage subsystem controller firmware and Storage Manager 
    host software releases to indicate which controller firmware and Storage 
    Manager host software release that they were first seen and documented.
    
    New limitations with Storage Manager Installer (SMIA) package version 
    10.30.xx.09 release.
    
    1.  Using VDS/VSS utilities (diskraid and diskpart) to create and map
        volumes may not immediately see the LUNs listed on the host due to
        PnP taking time to scan for the devices.  Wait for the devices to
        show up in device manager prior to using diskpart.
    
    2.  When writing an SMcli command file, the command reports that the file
        is written, but you cannot find the file.  User Account Control is
        enabled on the host, and it does not allow you to modify any files on
        the hard drive without permission. Disable this control, and rerun the
        SMcli command.
    
    3.  If you use a storage array as a boot device for the Windows Server 2003
        operating system, you cannot use the hibernation feature.
    
    New limitations with Storage Manager Installer (SMIA) package version 
    10.15.xx.08 release.
    
    1.  Reconfiguration operation (DRM) is delayed under some circumstances.
        When a drive fails before the DRM completes, it can take up to eight
        times as long for the DRM to complete.  DRM reconfigurations to RAID
        6 have the longest impact since there are four times as many calculations
        and writes that have to occur compared to other RAID levels.
    
    2.  Host Software display of controller current rate is wrong below 4Gbps.
        Host Software Client - AMW - Logical/Physical View - Controller Properties
        - Host Interfaces - Current rate is displaying "Not Available" when the
        controller negotiated speed is 2Gbps.  When the controller negotiated
        speed is reduced to 1GBs, the Current rate displays "2Gbps"
    
    New limitations with Storage Manager Installer (SMIA) package version 
    10.10.xx.xx release (controller firmware 07.10.xx.xx).
    
    1.  Controller Alarm Bell icon does not appear as a flashing icon
        indicator on the screen to get the user's attention but the icon
        does change appearances.
    
    2.  Miswire of drive tray cabling with DS4700 and DS4200 can cause
        continuous reboot of a controller.  To correct this situation, power
        down the subsytem, cable the drive trays correctly, and power the
        subsystem back up.
    
    3.  Controller button may appeared enabled and mislead the user that
        a controller is selected where in fact, a controller was not 
        highlighted for the botton to appear ready.
    
    4.  Search key is not marked correctly in that page due a JavaHelp 
        Bug with JavaHelp 2.0_01.  A search for keyword "profile" ended
        with phase "prese 'nting p' rofile" being marked. 
    
    5.  storageArrayProfile.txt should be renamed as storageSubsystemProfile.txt
        in Support Data.
    
    6.  Bullets Incorrectly Placed in Volume Modification Help Page
    
    7.  Unable to Escape out of Help Display.  User will be required to 
        close the window by using window close procedure (exit, etc.)
    
    8.  Bullets and Descriptions not alligned into same line in "Viewing
        mirror properties".
    
    9.  The Help window is not getting refreshed properly when using the 
        AMW.Help window.  Workaround is to close and reopen SANtricity.
    
    10.  CLI command failure for creation of volume(s) if capacity parameter
         syntax is not specified.  A space will need to be used between the
         integer value and the units used in the capacity option of this 
         command or, "create volume volumeGroup[4] capacity=15 GB…".
    
    11.  Customer will see high ITW counts displayed in GUI (RLS feature) 
         and logs (files) for diagnostics (support bundle, DDC, etc.) and
         may be concerned that he has a problem.  This will not cause a 
         Critical MEL event.  Known problem previously restricted, when a
         DS4700 or DS4200 controller reboots, these counters increment.
    
    12.  Single tray powercycle during IO activity causes drives in tray to become
         failed.  Customer may see loss of drive (failed) due to timing issue
         of drive detection & spin-up of the drive.  There are one of two
         conditions that result on power-up:
           - (Most likely) Drive will be marked as optimal/missing with
             the piece failed, or
           - (rarely) Drive will be marked as failed with the piece
             failed.
         Workaround is to unfail (revive) drive which restarts reconstruction
         of all pieces.
    
    13.  Event log critical Event 6402 was reported after creating 64 mirror 
         relations.  Eventually,  the mirror state  transitions to synchronizing
         and proceeds to completion on mirror creation.  Workaround is to 
         ignore the MEL logging since this occurs on creation of mirror volumes.
    
    14.  Reconfiguration operations during host IO may result in IO errors when
         arrays contain more than 32 LUNs.  These operations include Dynamic
         Capacity Expansion, Defragmentation, Dynamic Volume Expansion, Dynamic
         RAID Migration.  The workaround is to quiesce host IO activity during
         reconfiguration.
    
    15.  Heavy IO to a narrow volume group of SATA drives can result in host IO
         timeouts.  A narrow volume group refers to an array built of very few
         drives; namely 1 drive RAID 0, 1x1 RAID 1, and 2 + 1 RAID 5.  The workaround
         is to build arrays of SATA drives out of 4 + 1 or greater.
    
    16.  When managing the storage subsystem in-band, the upgrade utility will show
         the upgrade as failed.  This is because of the update and reboot of the
         controllers when activating the new firmware.  SMagent is not dynamic and
         will need to be restarted to reconnect to the storage subsystem.
    
    17.  Selecting and dragging text within the storage profile window causes the
         window to be continuously refreshed.  Work around is to select and copy,
         do not drag the text.
    
    18.  When configuring alerts through the task assistant, the option stays open
         after selecting OK.  The window only closes when the cancel button is
         selected.
    
    19.  The Performance Monitor displays error messages when the storage subsystem
         is experiencing exception conditions.  The performance monitor has a lower
         execution priority within the controller firmware than responding to system
         IO and can experience internal timeouts under these conditions.
    
    20.  Critical MEL event (6402 - Data on mirrored pair unsynchronized) can occur
         under certain circumstances with synchronous RVM.  The most likely scenario
         is when  both primary and secondary are on a remote mirror and an error occurs
         with access to that host.  Resynchronization should occur automatically, when
         automatic resynchronization is selected for a mirror relationship.  However
         if any of the host sites should go down during this interval, recovery by the
         user is required.
    
    21.  A persistent miswire condition is erroneously reported through the recovery
         guru even though the subsystem is properly wired.  The frequency of occurrence
         is low and is associated with an ESM firmware download or other reboot of the
         ESM.  The ESM that is reporting the problem must be reseated to eliminate the
         false reporting.  Not all miswire conditions are erroneous and must be evaluated
         to determine the nature of the error.
    
    22.  Drive path loss of redundancy has been reported during ESM download.  This
         occurs when a drive port is bypassed.  In some instances this is persistent
         until the drive is reconstructed.  In other cases it can be recovered through
         an ESM reboot (second ESM download, ESM pull and replace).
    
    23.  Unexpected drive states have been observed during power cycle testing due to
         internal controller firmware contention when flushing MEL events to disk.  The
         drives have been observed as reconstructing or replaced when they should have
         been reported as failed.  Also volume groups have been reported degraded when
         all drives were assigned and optimal.  An indication that this is the situation
         would be when drive reconstruction has not completed in the expected amount of
         time and does not appear to be making any progress.  The work around is to reboot
         the controller owning the volume where the reconstruction has stalled.
    
    24.  Sometimes when an ESM is inserted a drive's fault line is asserted briefly.  The
         fault line almost immediately returns to inactive, but the ESMs may bypass the
         drive.  In these circumstances, the administrator will have to reconstruct the
         failed drive.
    
    25.  After a drive fail, a manually initiated copyback to a global hot spare may also
         fail.  The work around is to remove the failed drive and reinsert it, then the
         copyback should resume and complete successfully.
    
    26.  When an erronieous miswire condition occurs (as mentioned above in 21), the
         recovery guru reports the miswire on one controller but not on the other.  In
         this situation, ignore the other controller and use the information supplied
         by the controller reporting the problem.
    
    27.  Occasionally a controller firmware upgrade to 07.10 will unexpectedly reboot a
         controller an extra time.  This could generate a diagnostic data capture, however
         the firmware upgrade is always successfull.
    
    28.  When managing previous releases of firmware (06.19 and prior), "working" gets
         displayed as "worki" during volume creation.
    
    29.  The Performance Monitor error window does not come to the front.  You must
         minimize all other foreground windows to get to the error popup window.
    
    30.  When a disk array is in a degraded state, the array will report "needs attention"
         to both the EMW and the AMW.  After taking appropriate corrective action, the
         AMW view of the array will report "fixing" but the EMW state remains at "needs
         attention".  Both statuses are valid, when the fault state is resolved both
         views will change to "optimal".
    
    31.  Storage subsystem loses in-band connectivity during volume creation.  This is
         caused by the controller logout to all hosts that are in the default host
         group when those hosts have QLogic HBAs which is not tolerant of the controller
         initiated logout.  The work around is to first create the host group and host
         port mappings prior to creation of volumes.  Then on volume creation avoid
         using the default host group.
    
    32.  When defining additional LUN mappings to a host, the volume name moves down to
         the bottom of the visible list making it difficult to keep track of the list.
    
    33.  A Windows server will experience a Blue Screen and will need to be rebooted when
         one or more controllers go offline in a storage subsystem.  A LUN/path may be in
         the process of being removed because an HBA has not reestablished a login with
         the controller and the PnP process will remove all LUNs associated with that
         path.  The timing of this should not be seen unless the customer is experiencing
         major problems with controllers going into offline states.
    
    34.  With SMProvider installed, the disk management on the server does not complete
         within 1 hour for a configuration of 20 or more storage subsystems attached on
         the subnet.  This is an issue with the auto-discovery of storage IP addresses
         by the SMProvider that supports the VDS/VSS feature of Windows.  On installation
         of the SMProvider, add all of the IP addresses for the storage subsystems into
         the registry.  On reboot, the registry contains the list of IP addresses and
         avoids the auto-discovery delay.  The registry location is:
           HKEY_LOCAL_MACHINE\SOFTWARE\Storage\SMprovider /v IpAddresses /t REG_SZ /d
         If the value is empty, the providers will use the auto-discovery method.
    
    35.  Result of an installation not completing normally because of a crash, blue
         screen, or other interruption will prevent the SMclient from being able to
         uninstall.  This is because the InstallAnywhere program writes to the ZeroG
         registry file at the very end of the installation process.  Reinstall the
         package to overwrite the installation and populate the ZeroG registry.
    
    36.  Using ALT-Q to access the QLogic HBA BIOS will hang the host, use CTL-Q instead.
    
    37.  Intermittently the flashcopy utility using the VSS provider fails to create
         persistent flashcopies.  The flashcopy volume is created at the storage
         subsystem and the volume mappings complete successfully, but after about
         one minute the vshadow utility removes the volume because Microsoft's PnP
         driver does not detect the flashcopy volume in time.  If a flashcopy failure
         has occurred, or the limit on flashcopies has been reached, remove any
         unnecessary flashcopies on the storage subsystem and retry the failed
         flashcopy request.
           Please note that some utilities such as NetBackup do not automatically clean
           up the failed request by removing these failed flashcopies from the storage
           array.
    
    38.  Startup of MS DISKRAID utility executing through VDS occasionally reports an
         error.  The following message is reported:
           "Diskraid encountered a fatal error while initializing.  The following
            information may help diagnose the error:
               Error: 0x80080005
               Location Code: 2"
         The server must be rebooted to recover, shutdown and restart of the VSS/VDS
         service does not fix the problem.
    
    
    Legacy restrictions that are still applicable:
     
    1. Reflected Fibre Channel (FC) OPN frames occurs when intermixing the 
       EXP810, EXP710 and EXP100s behind DS4700 or DS4800 storage subsystems. 
       This behavior causes excessive drive side timeout, drive side link down 
       and drive side link up events be posted in the DS4000 storage subsystem 
       Event log (MEL.) It might also cause drives to be by-passed or failed by 
       the controller. NEW DRIVE SIDE FC CABLING REQUIREMENT MUST BE ADHERED TO 
       WHEN HAVING EXP100 CONNECTED TO THE DS4700 OR DS4800 STORAGE SUBSYSTEMS. 
       Please refer to the latest version of the Installation, User's and 
       Maintenance Guide for these storage subsystems that are posted in the IBM 
       DS4000 Support web site for more information.
       http://www.ibm.com/servers/storage/support/disk/
      
    2. Can not increase the capacity of RAID arrays.
       RAID arrays with certain combinations of selected segment size and 
       number of drives that made up the arrays will exceed the available 
       working space in controller dacstore, causing a reconfiguration request 
       (like expanding the capacity of the array) to be denied. These 
       combinations are generally the largest segment size (512KB) with the 
       number of drives in the array is 15 drives or more. There is no 
       work-around. C324144 105008 
    
    3. Interoperability problem between the Tachyon DX2 chip in the DS4500 and
       the DS4300 storage subsystem controllers and the Emulex SOC 422 chip in 
       the EXP810 expansion enclosure ESMs causing up to 5 Fibre Channel loop 
       type errors to be posted in the DS4000 storage subsystem Major Event Log 
       during a 24 hour period. There is a small window in the SOC 422 chip 
       that multiple devices can be opened at one time. This ultimately leads 
       to Fibre Channel loop errors of Fibre Channel link up/down, Drive 
       returned CHECK CONDITION, and Timeout on drive side of controller. IBM
       recommends the use of the Read-Link-Status function to monitor drive loop
       for any problems in the drive loop/channel. There is no work-around.
    
    4. The single digit of the Enclosure IDs for all enclosures (including the
       DS4000 storage subsystem with internal drive slots) in a given redundant 
       drive loop/channel pair must be unique. For example, with four 
       enclosures attached to the DS4300, the correct enclosure ID settings 
       should be x1, x2, x3, and x4 (where x can be any digit that can be set). 
       Examples of incorrect settings would be 11, 21, 31, and 41 or 12, 22, 
       32, and 62. These examples are incorrect because the x1 digits are the 
       same in all enclosure IDs (either 1 or 2). 
       
       If you do not set the single digit of the enclosure IDs to be unique 
       among enclosures in a redundant drive loop/channel pair, then drive 
       loop/channel errors might be randomly posted in the DS4000 subsystem 
       Major Event Log (MEL), especially in the cases where the DS4300 storage 
       substems are connected to EXP810s and EXP100s. In additon, enclosure IDs 
       with same single digits in a redundant drive loop/channel pair will 
       cause the DS4000 subsystem controller to assign a soft AL_PA address to 
       devices in the redundant drive loop/channel pair. The problem with soft 
       AL_PA addressing is that AL_PA address assignment can change between 
       LIPs. This possibility increases the difficulty of troubleshooting drive 
       loop problems because it is difficult to ascertain whether the same 
       device with a different address or a different device might be causing a 
       problem.  
    
    5. In DS4000 storage subsystem configurations with controller firmware 
       6.15.2x.xx and higher installed, the performance of write intense 
       workloads such as sequential Tape restores to DS4000 Logical drives with 
       large I/O request sizes (e.g. 256kB) is degraded if the DS4000 logical 
       drives are created with small segment sizes such as 8KB or 16KB. The 
       work around is to create the DS4000 logical drives with segment size of 
       64KB or higher.
    
    6. Do not pull or insert drives during the drive firmware download. 
       In addition, ALL I/Os must also be stopped during the drive firmware
       download. Otherwise, drives may be shown as missing, unavailable or
       failed. 
    
    7. Do not perform other storage management tasks, such as creating or 
       deleting logical drives, reconstructing arrays, and so on, while 
       downloading the DS4000 storage subsystem controller firmware and DS4000 
       EXP ESM firmware. It is recommended that you close all storage 
       management sessions (other than the session that you use to upgrade
       the firmware) to the DS4000 storage subsystem that you plan to update.
        
    8. For Microsoft Windows Server 2003 R2 operating systems. When loading the 
       Microsoft Hot fix KB916048, required in installing Storage Manager, if the 
       IBM xSeries Server hangs during reboot it may be resolved by using the 
       latest Broadcom driver for the Bcom HT1000. 
     
        
    ========================================================================
                    
    1.3  Enhancements
    -----------------
      
       The DS Storage Manager version 10.30.xx.09 host software for 
       Microsoft Windows Server 2003 and Server 2008 operating systems 
       in conjunction with controller firmware version 7.30.xx.xx provides 
       supports for  
    
       - Support for the new DS5300 Storage Controller Subsystem model 1818-53A, 
         which supports the attachment of the new EXP5000 Storage Expansion 
         Enclosure Subsystem model 1818-D1A.
         
       - Support for the new DS5100 Storage Controller Subsystem model 1818-51A, 
         which supports the attachment of the new EXP5000 Storage Expansion 
         Enclosure Subsystem model 1818-D1A.
    
       Please refer to the New Features section of the IBM System Storage 
       DS Storage Manager Version 10 Installation and Host Support Guide 
       for additional information about the IBM DS Storage Manager version 
       10 enhancements.
                 
    =======================================================================
                
    1.4 Level Recommendation and Prerequisites for the update
    -----------------------------------------------------------
    
    Note: The IBM Storage Manager host software version 10.30 for Microsoft 
          Windows operating systems, new features and changes are described 
          in the corresponding Change History document. Please refer to this 
          document for more information on new features and modifications.
    
       Microsoft Windows NT4 SP6 and Windows 2000 SP4 operating systems are not 
       supported for this release of IBM DS Storage Manager version 
       10.30.xx.xx. The only supported Microsoft operating systems are the x86, 
       x64 and IA64 editions of Windows Server 2003 with SP2, the x86 and x64 
       editions of Windows Server 2008, and Windows Vista 32bit. 
       
       For the 32bit Windows Vista, Server 2003 (X86), or Server 2008 (x86) 
       editions, IBM xSeries and other Intel-based servers with minimum 1024MB 
       Memory with at least 512KB L2 Cache Pentium III 1Ghz processor(s) is 
       recommended.
       
       For the Intel Itanium II 64bit Microsoft Windows Server 2003 edition, IBM 
       xSeries and other Intel-based servers with minimum 1024MB Memory with 
       Intel Itanium II processor(s) is recommended.
      
       For the X64 64bit (AMD64 and EM64T) Microsoft Windows Server 2003 and 
       Microsoft Windows Server 2008 edition, IBM xSeries and other servers 
       with minimum 2048MB Memory with Intel EM64T or AMD AMD64 processor(s) is 
       recommended.
       
       (also see Dependencies section)
      
       
      Client Code levels at time of release are as followed
      ---------------------------------------------------------
    
      Important: 
        1. This release of IBM DS Storage Manager host software Client 
           supports managing all DS4000/DS500 storage subsystems with general 
           released firmware versions from 05.30.xx.xx up to 07.30.xx.xx. 
     
        2. There are three separate IBM DS Storage Manager host software 
           version 10.30 packages for the following Microsoft Windows OSes -
           Windows Vista 32bit, Windows Server 2003 Intel Architecture (x86), 
           and Windows Server 2008 (x86); Windows Server 2003 Intel 
           Architecture Itanium II 64bit (IA-64); Windows Server 2003 (x64) and 
           Windows Server 2008 (x64). Please download the correct one for your 
           operating system environment.
           
        3. When using the Fibre Channels host bus adapter device driver based 
           on the Microsoft STORport miniport drive model, you must install 
           Microsoft Windows Server 2003 STORport hot-fix KB932755 - An updated 
           Storport storage driver (version 5.2.3790.4021)
    
      Operating Systems support Packs:
         - Windows Server 2008: SP1
         - Windows Server 2003: SP2  
         - Windows Vista 
        
      For Microsoft Windows Server 2003 x86 (32bit), Server 2008 x86
      only:
         Starting with the DS4000 storage manager version 10.10, there  
         is a controller firmware upgrade tool included. The version
         of Storage Manager firmware upgrade installer is 
         SMFWUpgInstaller-WS32-10.15.35.02. This installer will install
         the following versions of firmware upgrade packages:
         
         1. SMfwupgrade - 10.15.G5.30
         2. SMfirmware - 10.15.G5.00
         
         Starting with the DS4000 storage manager version 9.12, all of the host-
         software packages are included in a single host-software installer 
         wizard. During the execution of the wizard, the user will have a choice 
         to install all or only certain software packages depending the need for 
         a given server. The version of the host software installer wizard for 
         this release is SMIA-WS32-10.30.35.09.exe. This wizard will install the 
         following version of the host-software packages:
         
         1. IBM DS Storage Manager Client version: 10.30.G5.10
         2. IBM DS Storage Manager MPIO/DSM version:   01.03.0305.0013  
            Note: The MPIO/DSM multipath driver is supported with controller
                  firmware version 06.12.xx.xx or higher. 
                  For Window Server 2003 and Windows Server 2008, 
                  install the latest STORport driver with the MPIO/DSM 
                  multipath driver.
    
         3. IBM DS Storage Manager Agent version:  10.00.35.05
         4. IBM DS Storage Manager Utilities version: 10.00.35.06
         5. IBM DS Storage Manager ESM version:       10.30.G5.01
    
        
         In addition, for DS4000/DS5000 configurations with Microsoft Windows 
         servers using Veritas Volume Manager (DMP) 4.2 and 4.3 as multipath 
         driver, you have to obtain the correct asl file for DS4000/DS5000
         storage subsystem using the following Veritas Support URL.
    
         http://seer.support.veritas.com/docs/273458.htm (for DMP 4.2)
         http://seer.support.veritas.com/docs/281172.htm (for DMP 4.3)
    
    
      For Microsoft Windows Server 2003 Intel Itanium II 64bit (IA64) edition 
      only:
         Starting with the DS4000 storage manager version 10.10, there  
         is a controller firmware upgrade tool included. The version
         of Storage Manager firmware upgrade installer is 
         SMFWUpgInstaller-WS64-10.15.35.02. This installer will install
         the following versions of firmware upgrade packages:
         
         1. SMfwupgrade - 10.15.G5.30
         2. SMfirmware - 10.15.G5.00  
      
         Starting with the DS4000 storage manager version 9.12, all of the 
         host-software packages are included in a single host-software 
         installer wizard. During the execution of the wizard, the user will have 
         a choice to install all or only certain software packages depending the 
         need for a given server. The version of the host-software installer 
         wizard for this release is SMIA-WS64-10.30.35.09.exe. This wizard 
         will install the following version of the host-software packages:
    
         1. IBM DS Storage Manager Client version: 10.30.G5.10
         2. IBM DS Storage Manager MPIO/DSM version:   01.03.0305.0013  
            Note: The MPIO/DSM multipath driver is supported with controller
                  firmware version 06.12.xx.xx or higher.
      
         3. IBM DS Storage Manager Agent version:  10.00.35.05
         4. IBM DS Storage Manager Utilities version: 10.00.35.06
         5. IBM DS Storage Manager ESM version:       10.30.G5.01     
    
     
      For Microsoft Windows Server 2008 x64 and Microsoft Windows Server 2003 
      X64 64bit (AMD64 and EM64T) edition only:
      
         Starting with the DS4000 storage manager version 10.10, there  
         is a controller firmware upgrade tool included. The version
         of Storage Manager firmware upgrade installer is 
         SMFWUpgInstaller-WSX64-10.15.35.02. This installer will install
         the following versions of firmware upgrade packages:
         
         1. SMfwupgrade - 10.15.G5.30
         2. SMfirmware - 10.15.G5.00  
      
      
         Starting with the DS4000 storage manager version 9.12, all of the 
         host-software packages are included in a single host-software 
         installer wizard. During the execution of the wizard, the user will have 
         a choice to install all or only certain software packages depending the 
         need for a given server. The version of the host-software installer 
         wizard for this release is SMIA-WSX64-10.30.35.09.exe. This wizard 
         will install the following version of the host-software packages:
    
         1. IBM DS Storage Manager Client version: 10.30.G5.10
         2. IBM DS Storage Manager MPIO/DSM version:   01.03.0305.0013  
            Note: The MPIO/DSM multipath driver is supported with controller
                  firmware version 06.12.xx.xx or higher.
    
         3. IBM DS Storage Manager Agent version:  10.00.35.05
         4. IBM DS Storage Manager Utilities version: 10.00.35.06
         5. IBM DS Storage Manager ESM version:       10.30.G5.01     
         
      For Windows Vista 32bit (IA32/X86) only:
      
         Starting with the DS4000 storage manager version 10.10, there  
         is a controller firmware upgrade tool included. The version
         of Storage Manager firmware upgrade installer is 
         SMFWUpgInstaller-WS32-10.15.35.02. This installer will install
         the following versions of firmware upgrade packages:
         
         1. SMfwupgrade - 10.15.G5.30
         2. SMfirmware - 10.15.G5.00
         
         The version of the host software installer wizard for 
         this release is SMIA-WS32-10.30.35.09.exe. This wizard will 
         install the following version of the host-software packages:
         
         1. IBM DS Storage Manager Client version: 10.30.G5.10
    
     Refer to the http://www.ibm.com/servers/storage/support/disk IBM 
     System Storage™ Disk Storage Systems Technical Support web site for the 
     latest released code levels.
    
       
    =======================================================================
                
    1.5  Dependencies
    -----------------
    
       ATTENTION:
       
       1. DS4000 storage subsystem CONTROLLER FIRMWARE VERSION 06.1X.XX.XX 
          REQUIRES THAT THE FIRMWARE VERSION OF AN ATTACHED EXP700 ENVIRONMENTAL 
          SERVICE MODULE (ESM) BE AT VERSION 9326 OR HIGHER. IF THE EXP700 ESM 
          FIRMWARE IS EARLIER THAN THE 9326 VERSIONS, THE EXP700 ENCLOSURE AND 
          THE INSTALLED DRIVES MAY NOT BE DISPLAYED IN THE DS4000 SUBSYSTEM 
          MANAGEMENT WINDOW AFTER THE CONTROLLER FIRMWARE IS UPGRADED. THE 
          CURRENT RELEASE ESM FIRMWARE VERSION FOR THE EXP700 ESM IS 9330. 
    
       2. DS4000 STORAGE SUBSYSTEM CONTROLLER FIRMWARE VERSION 06.1X.XX.XX 
          REQUIRES THAT THE FIRMWARE VERSION OF AN ATTACHED EXP100 ENVIRONMENTAL 
          SERVICE MODULE (ESM) BE AT VERSION 955X OR HIGHER. IT IS NOT POSSIBLE 
          TO UPGRADE EXP100 ESM FIRMWARE VERSIONS THROUGH 953X TO VERSION 955X 
          WHEN THE CONTROLLER FIRMWARE IS AT 06.1X.XX.XX. TO DETERMINE THE 
          FIRMWARE LEVEL OF AN EXP100 ESM, IDENTIFY THE PRODUCT LABEL LOCATED AT 
          THE REAR OF THE EXP100 ENCLOSURE. ONLY LABELS ON WHICH THE FIELD 
          REPLACEABLE UNIT (FRU) PART NUMBER READS 25R0156 POSITIVELY INDICATE 
          THAT AN ESM MODULE IS RUNNING FIRMWARE VERSION 955X OR HIGHER. IF THERE 
          IS NO LABEL OR THE PART NUMBER ON THE LABEL DOES NOT READ 25R0156, THE 
          ESM MAY STILL HAVE THE FIRMWARE VERSION 955X OR HIGHER IF IT HAD BEEN 
          PREVIOUSLY UPGRADED. IF NECESSARY, CONTACT YOUR IBM REPRESENTATIVE, 
          SUPPORT, OR RESELLERS FOR ASSISTANCE. IN ADDITION, IT IS NOT POSSIBLE 
          TO UPGRADE THE ESM FIRMWARE FROM VERSION 953X TO VERSION 956X OR LATER 
          DIRECTLY. THE 953X ESM MUST BE UPGRADED TO VERSION 9554 FIRST BEFORE IT 
          CAN BE UPGRADED TO VERSION 956X.
          
       3. CURRENTLY, THE ONLY DS4000 STORAGE SUBSYSTEMS THAT ARE SUPPORTED BY 
          THE 06.12.XX.XX CONTROLLER FIRMWARE VERSION ARE THE DS4100 - ALL 
          MODELS, THE DS4300 WITH STANDARD (DUAL CONTROLLER) OR TURBO OPTIONS, 
          THE DS4400 AND THE DS4500. DO NOT DOWNLOAD THIS CONTROLLER FIRMWARE ON 
          ANY OTHER DS4000 STORAGE SUBSYSTEM. THERE IS NOT ANY CHECKING FOR THIS 
          RESTRICTION INSIDE THE STORAGE MANAGER CLIENT PROGRAM.
       
       4. The only DS4000 storage subsystems that are supported by the 
          06.14.xx.xx or higher (06.14.xx.xx, 06.15.xx.xx, 06.16.xx.xx, 
          06.19.xx.xx or 6.23.xx.xx) controller firmware version are the DS4200 
          (06.16.88.xx or higher), DS4300 Standard-dual controller or Turbo 
          models (06.19.xx.xx or higher), and the DS4500 (06.19.xx.xx or higher), 
          DS4700 (06.16.4x.xx or higher) and DS4800 (06.14.xx.xx or higher) 
          storage subsystems. Currently, there are not any controller firmware 
          packages version 06.14.xx.xx and higher for other DS4000 storage 
          subsystems. Do not download this controller firmware on any other 
          DS4000 storage subsystems.
    
       5. Always check the README files (especially the Dependencies section) 
          that are packaged together with the firmware files for any required 
          minimum firmware level requirements and the firmware download 
          sequence for the DS4000 drive expansion enclosure ESM, the DS4000 
          storage subsystem controller and the hard drive firmware.
    
       6. If the managed DS4000 storage subsystem had the FC/SATA intermix 
          premium feature enable, do not upgrade the controller firmware from 
          version 06.10.xx.xx to version 06.12.xx.xx until a FC/SATA intermix 
          premium feature key file is generated and available. Once the 
          controller firmware is upgraded to version 06.12.xx.xx, the FC/SATA 
          intermix premium feature will be shown as out-of-compliance and the 
          FC/SATA intermix premium feature key file is required to re-enable the 
          feature. When the FC/SATA intermix premium feature is in out-of-
          compliance state, LUNs management functions like creations, deletions 
          and modifications will not be operational. Please refer to the FC/SATA 
          intermix premium feature activation card that was shipped with the 
          FC/SATA intermix premium feature kit for instructions to generate the 
          required premium key file.
    
       7. The DS4700 and DS4800 storage subsystems do not support the attachment
          of the DS4000 EXP700 drive expansion enclosures. The EXP700 enclosure 
          must be upgraded into DS4000 EXP710 enclosure using the DS4000 EXP700 
          Models 1RU/1RX Switched-ESM Option Upgrade Kit before it can be 
          attached to the DS4700 and DS4800 storage subsystems.
    
       8. THE DS4000 STORAGE SERVER WITH CONTROLLER FIRMWARE VERSION 05.41.1X.XX
          MUST BE UPGRADED TO CONTROLLER FIRMWARE VERSION 05.41.5X.XX FIRST 
          BEFORE IT CAN BE UPGRADED TO CONTROLLER FIRMWARE VERSION 06.1X.XX.XX OR 
          LATER. OTHERWISE, THE ERROR 231-FIRMWARE INCOMPATIBLE WILL BE 
          DISPLAYED. 
          
       9. DS4000 storage subsystem controller firmware versions 6.12.16.xx or 
          higher and EXP100 storage expansion enclosure ESM firmware version 9563 
          or higher are required to provide support for the new 400G SATA drive 
          options and CRUs (P/Ns 39M4570 and 39M4575, respectively) in addition 
          to the new 250G SATA drive CRUs (P/N 40K6837.) This new 250G SATA drive 
          CRU is functionally equivalent to the previously-released CRUs (P/N 
          90P1349).
       
      10. The version 06.16.xx.xx of the DS4700 or DS4800 controller firmware 
          is not compatible with the EXP100 SATA drive expansion enclosures. DO 
          NOT download it into the DS4800 storage subsystems that have EXP100 
          drive expansion enclosures attached. After the 06.16.xx.xx controller 
          firmware is activated, the DS4800 storage subsystem will not recognize 
          the drives in EXP100 enclosures, causing loss of data availability to 
          the raid arrays and logical drives that are defined in those drives. 
          IBM recommends installing the controller firmware version 6.23.xx.xx 
          and higher in the DS4000 storage subsystems that have EXP100 SATA drive 
          expansion enclosure attached instead. 
     
      11. Controller firmware 06.16.xx.xx or higher is required to support
          EXP810 storage expansion enclosures.
    
      12. Controller firmware 06.16.4x.xx and higher is required for the DS4700
          -all models and the DS4800-model 80A/80H. These models do not support 
          older 06.16.xx.xx versions of controller firmware. The attachment of 
          EXP100 enclosures is ONLY supported for these models only if the 
          controller firmware is upgraded to version 6.23.xx.xx or higher.
    
      13. Controller firmware 06.16.88.xx and higher is required for the
          DS4200-all models. These models do not support older 06.16.xx.xx 
          versions of controller firmware. The attachment of EXP100, EXP710
          and EXP810 enclosures is not supported for these DS4200 models.
          
      14. When using STORport miniport version of the Fibre Channel host bus 
          adapter device driver, Windows Server 2003 service pack 1 must be 
          installed along with the Microsoft Windows Server 2003 STORport hot-
          fix KB916048 - An updated Storport storage driver (version 
          5.2.3790.2723) is available for Windows Server 2003. The Windows 
          Server 2003 service pack 1 and the STORport hot-fix 916048 are 
          available for download at the Microsoft support web site.
          
      15. The latest version of Microsoft Windows SCSIport and the STORport FC
          HBA device drivers do not support the BUSCHANGE=0 parameter. It 
          requires the DS4000 storage subsystem controller firmware to be 
          compatible with the MS Plug and Play driver. Not all versions of the 
          DS4000 storage subsystem controller firmware are compatible with the 
          Microsoft Plug and Play driver. Currently, only the controller 
          firmware versions that are listed in the table below for each of the 
          DS4000 subsystems, which support the SCSIport device drivers with 
          BUSCHANGE parameter set to Microsoft required default value of 2, are 
          compatible with the MS Plug-and-Play driver.
       
             ------------------------------------------
            | DS4000             | Controller Firmware |
            | Storage Subsystem  |  Version Required   |
             -------------------------------------------
            |  DS4700            | 06.16.8x.xx or later|
            |  DS4800            | 06.15.2x.xx         |
            |                    | 06.16.8x.xx or later|
            |  DS4500            | 06.12.27.xx or later|
            |  DS4400            | 06.12.27.xx or later|
            |  DS4300            | 06.12.27.xx or later|
            |  DS4200            | 06.16.88.xx or later|
            |  DS4100            | 06.12.27.xx or later|
             ------------------------------------------
           
          Do not use STORport miniport device driver or FAStT/DS4000 FC HBA 
          SCSIport device driver version 9.1.2.11 and higher in the Microsoft 
          Windows servers that have IO access to the DS4000 storage subsystems 
          with controller firmware that are not listed in the controller 
          firmware table above. Please check with your IBM reseller, IBM 
          representative, or the DS4000 interoperability matrix for information 
          on future DS4000 storage subsystems support of this device driver 
          without BUSCHANGE=0 parameter.
     
      16. Controller firmware 06.19.xx.xx and higher is required for the DS4300- 
          standard-dual controller or Turbo models and the DS4500-all models for 
          attaching the EXP810 storage expansion enclosures.
      
      17. Controller firmware 06.23.xx.xx and higher is required for the DS4700- 
          all models and the DS4800-all models for attaching EXP810, EXP710 and 
          EXP100 together behind a DS4000 storage subsystem. The intermix of 
          EXP810 and EXP100 behind a DS4700 or DS4800 is supported only with 
          controller firmware version 6.23.xx.xx and higher.
          
      18. The DS5100 and DS5300 storage subsystems do not support the attachment
          of the DS4000 EXP100, EXP700, EXP710 drive expansion enclosures. 
    
      19. The DS5000 EXP5000 drive expansion enclosure is supported attached
          to the DS5100 and DS5300 only.      
      
    
       IBM DS Storage Manager version 10.30 provides full management 
       support for DS4000/DS5000 storage subsystems that have controller firmware 
       version 05.30.xx.xx or higher.
        
                
    =======================================================================
                  
    2.0   Installation and Setup Instructions
    -----------------------------------------
    
    Note: The web-download Storage Manager version 10.30 host software package 
          must be first unpacked (unzipped) into a user-defined directory. Then,
          go to this directory, locate the Windows directory to access the 
          Storage Manager version 10.15 Controller Firmware upgrade tool 
          and the version 10.30 host software installer wizard.
    
    
    2.1  Step-by-step instructions for this code update are as follows
    ------------------------------------------------------------------
                         
    1. Install and update the device driver for the IBM FAStT, FC-2, FC2-133
       single port or dual port, FC 4Gbps PCIx single port or dual port,
       or Qlogic 4Gb FC PCIe for IBM System X Fibre Channel Host Bus Adapters.
                    
       a. Install the hardware by using the instructions that come with the 
          adapter.
       b. Review section 3.2 in this readme file for the minimum recommended
          device driver version for your Fibre Channel Host Bus Adapters. 
       c. Install the IBM DS4000 Host Adapter device driver by using the 
          instructions provided in the readme.txt file located in either the 
          Host_Adapter directory on this installation CD or from the 
          appropriate driver package that is downloaded from the IBM Support 
          Web site.
    
    
    2. If there is previous version 7.x, 8.x or 9.10 of the IBM DS4000 
       storage manager host software installed in the system, you have to 
       uninstall it first before installing the new version of the storage 
       manager host software. 
       
       IMPORTANT: For servers with boot LUNs in the DS4000 storage subsystems 
       (aka. SAN Boot or Root Boot), a special utility in the 
       RDAC_UninstallUtil_for_BootFromSANConfigurations directory must be run 
       first before Uninstalling the RDAC, especially in the following server 
       configuration - W2K server with DS4000 Storage Manager 8.4 RDAC installed. 
       Please refer to the README in the 
       RDAC_UninstallUtil_for_BootFromSANConfigurations directory for 
       instructions on running the utility. NOTE: This utility can also be used 
       to recover from a failed uninstalling of the RDAC in non-SAN boot 
       Microsoft Windows environments which resulted in a failed reboot of the 
       Windows operating system.
       
       For instruction to uninstall the DS4000 storage manager host software, 
       please refer to the IBM System Storage DS Storage Manager Version 10 
       Installation and Host Support Guide.
    
       If the previously installed DS4000 storage manager version is of 10 or 
       later, the DS4000 storage manager host software can be updated with the new 
       code from the installer without the need of uninstalling the existing 
       storage manager host software packages first. Just click "Yes" in the 
       window that the installer displays, stating that there are already 
       installed DS4000 storage manager host software in the server and whether 
       you want to update it with the new code. 
    
    3. Install the new storage manager host software from the appropriate 
       CD-ROM directory for your Operating Systems or from the host software 
       package that you downloaded from the IBM Support Web site. Refer to the 
       IBM System Storage DS Storage Manager Version 10 Installation and 
       Host Support Guide for detailed installation instructions.
       
    4. Upgrade the DS4000/DS5000 storage subsystem firmware in the following order - 
             1. Controller firmware and NVSRAM
             2. ESM firmware
             3. Drive firmware
       Refer to the IBM System Storage DS Storage Manager Version 10 
       Installation and Host Support Guide or the online help in the Subsystem 
       Management window for detailed instructions.   
       
       ATTENTION: Always check the README files (especially the Dependencies 
       section) that are packaged together with the firmware files for any 
       required minimum firmware level requirements and the firmware download 
       sequence for the DS4000/DS5000 drive expansion enclosure ESM, the 
       DS4000/DS5000 storage subsystem controller and the hard drive firmware.
    
    5. (if applicable) Re-enable the FC/SATA intermix premium feature using 
       the premium key file.
       
       
       Refer to the http://www.ibm.com/servers/storage/support/disk IBM System 
       Storage™ Disk Storage Systems Technical Support web site for the the 
       latest DS Storage Manager host software, the DS4000/DS5000 controllers 
       firmware, the drive expansion enclosure ESM firmware and the hard disk 
       drive code. 
    
       
    =======================================================================
       
    2.2 Refer to the Host_Adapter directory on the installation CD for 
        the applicable drivers.  
         
       Refer to the http://www.ibm.com/servers/storage/support/disk IBM 
       System Storage™ Disk Storage Systems Technical Support web site for the 
       latest supported host adapters, device drivers, and updated readme. 
          
    =======================================================================
                                    
    2.3  Helpful Hints
    ------------------
    
    1. The DS4500 and DS4300 storage subsystem have updated recommended drive-side 
       cabling instructions. The DS4500 instructions are documented in the IBM 
       System Storage DS4500 Installation, Users. and Maintenance Guide (GC27-
       2051-00 or IBM P/N 42D3302). The DS4300 instructions are documented in the 
       IBM System Storage DS4300 Installation, Users. and Maintenance Guide 
       (GC26-7722-02 or IBM P/N 42D3300). 
       
       Please follow the cabling instructions in these publication to cable the 
       new DS4500 and DS4300 setup. If you have an existing DS4500 setup with 
       four drive side minuhub installed that was cabled according to the 
       previously recommended cabling instructions, please schedule down time as 
       soon as possible to make changes to the drive side FC cabling. Refer to 
       the IBM System Storage DS4500 and DS4300 Installation, Users. and 
       Maintenance Guide for more information. 
    
    2. If you are unable to see the maximum number of drives during 
       Automatic Configuration, you should be able to use Manual 
       Configuration to select individual drives and select the maximum 
       number of drives allowed.
    
    3. Depending on the storage subsystem that you have purchased, you
       may have to purchase the DS4000 storage partitioning premium feature
       option or an option to upgrade the number of supported partitions
       in a storage subsystem. Please see IBM Marketing representatives
       or IBM resellers for more information.
       
       - IBM DS4100 storage subsystem (machine type 1724): The standard and 
         single controller configuration does not have the DS4000 storage 
         partitioning premium enabled. Four partition, eight partition, 
         sixteen and an upgrade from four to eight partition storage 
         partitioning premium feature options can be purchased. 
    
       - IBM DS4200 storage subsystem (machine type 1814): Depending on the 
         ordering channels, the DS420 storage subsystem is either shipped with 
         2 storage partitions or with a user selected 2, 4, 8, 16 or 64 storage 
         partitions. If the DS4200 storage subsystem is ordered with less than 
         64 partitions, various storage partition feature upgrade options can 
         be purchased to increase the maximum number of supported storage 
         partitions.
    
       - IBM DS4300 storage subsystem (machine type 1722): The standard
         configuration does not have the DS4000 storage partitioning premium
         enabled. Four partition, eight partition, sixteen and an upgrade 
         from four to eight partition storage partitioning premium feature
         options can be purchased. The IBM DS4300 Turbo option comes with
         8 partition storage partitioning premium option installed. An
         upgrade to 64 partitions can be purchased for the IBM DS4300 
         Turbo option. 
    
       - IBM FAStT200 (machine type 3542: The standard configuration has 16
         partition storage partitioning premium option installed. No additional
         storage partitioning premium feature options can be purchased for 
         these storage subsystems.
    
       - IBM FAStT500 and DS4400 storage subsystems (machine type 3552 and 
         1742 - models 1RU and 1RX, respectively): The standard configuration
         has 64 partition storage partitioning premium option installed. No 
         additional storage partitioning premium feature options can be 
         purchased for these storage subsystems.
    
       - IBM DS4500 storage subsystem (machine type 1742 - models 90X and
         90U): The standard configuration has 16 partition storage partitioning
         premium option installed. An upgrade from 16 to 64 partition storage
         partitioning premium feature option can be purchased.
    
       - IBM DS4700 storage subsystem (machine type 1814): Depending on the 
         ordering channels, the DS4700-model 70 storage subsystem is either 
         shipped with 2 storage partitions or with a user selected 2, 4, 8, 16, 
         32, 64 or 128 storage partitions. Similarly, the DS4700-model 72 
         storage subsystem is either shipped with 8 storage partitions or with 
         a user selected 8, 16, 32, 64 or 128 storage partitions. If the DS4700 
         storage subsystem is ordered with less than 128 partitions, various 
         storage partition feature upgrade options can be purchased to increase 
         the maximum number of supported storage partitions.
    
       - IBM DS4800 storage subsystem (machine type 1815): Depending on the 
         ordering channels, the DS4800 storage subsystem is either shipped with 
         8 storage partitions or with a user selected 8, 16, 32, 64, 128, 256 
         or 512 storage partitions. If the subsystem is ordered with less than 
         512 partitions, an upgrade from 8 to 16, 8 to 32, 8 to 64, 16 to 32, 
         16 to 64, 32 to 64, 32 to 128, 64 to 128, 64 to 256, 128 to 256, 
         128 to 512, or 256 to 512 partition storage partitioning premium 
         feature option can be purchased.
         
       - IBM DS5300 and DS5100 storage subsystem (machine type 1818): 
         the DS5300 and DS5100 storage subsystem is shipped with a user 
         selected 8, 16, 32, 64, 128, 256 or 512 storage partitions. If the 
         subsystem is ordered with less than 512 partitions, various storage 
         partition feature upgrade options can be purchased to increase the 
         maximum number of supported storage partitions.
    
    
    4. Do not delete the Access LUN or Access Volume. The Access LUN is required
       by the SMClient to communicate with the storage controllers when using the 
       in-band management method.
      
    5. The DS4000 controller host ports or the Fibre Channel HBA ports can not 
       be connected to a Cisco FC switch ports with "trunking" enable. You might
       encounter failover and failback problems if you do not change the Cisco
       FC switch port to "non-trunking" using the following procedure:
     
       a. Launch the Cisco FC switch Device Manager GUI. 
       b. Select one or more ports by a single click.
       c. Right click the port(s) and select Configure, a new window pops up
       d. Select the "Trunk Config" tab from this window, a new window opens
       e. In this window under Admin, select the "non-trunk" radio button, it is
          set to auto by default.
       f. Refresh the entire fabric.      
    
    6. When making serial connections to the DS4000 storage controller, the 
       baud rate is recommended to be set at either 38200 or 57600. Note: Do 
       not make any connections to the DS4000 storage subsystem serial ports 
       unless it is instructed by IBM Support. Incorrect use of the serial 
       port might result in lost of configuration, and possibly, data. 
    
    7. Fabric topology zoning requirement. To avoid possible problem at the 
       host level, it is best practice that all Fibre Channel (FC) Switches 
       must be zoned such that a single FC host bus adapter can only access 
       one controller per storage array. In addition, this zoning requirement 
       also ensures the maximum number of host connections can be seen and 
       log into the controller FC host port. This is because if a FC HBA port 
       is seen by both controller A and B host ports, it will be counted as 
       two host connections to the storage subsystem - one for controller A 
       port and one for controller B port.
       
       Note: The DS4000 storage subsystems DS4500, DS4400 and FAStT500 (IBM 
       machine type 1742 and 3552) have two ports per controller - one per 
       minihub slot. The DS4000 storage subsystems DS4300 (IBM machine type 1722) 
       and DS4100 (IBM machine type 1724) have two ports per controller. The 
       DS4000 storage subsystem FAStT200 (IBM machine type 3542) has only one 
       port per controller. The DS4800 storage subsystem (IBM machine type 1815) 
       has four ports per controller.
    
    8. All enclosures (including DS4000 storage subsystem with internal drive 
       slots) on any given drive loop/channel should have complete unique ID's,
       especially the single digit (x1) portion of the ID, assigned to them. 
       For example, in a maximum configured DS4500 storage subsystem, enclosures 
       on one redundant drive loop should be assigned with id's 10-17 and 
       enclosures on the second drive loop should be assigned with id's 20-27. 
       Enclosure id's with the same single digit such as 11, 21 and 31 should 
       not be used on the same drive loop/channel. 
           
       In addition, for enclosures with mechanical enclosure ID switch like 
       DS4300 storage subsystems, EXP100 or EXP710 storage expansion 
       enclosures, do not use enclosure ID value of 0. The reason is with the 
       physical design and movement of the mechanical enclosure ID switch, it 
       is possible to leave the switch in a “dead zone” between ID numbers, 
       which return an incorrect enclosure ID to the storage management 
       software. The most commonly returned enclosure ID is 0 (zero). In 
       addition to causing the subsystem management software to report 
       incorrect enclosure ID, this behavior also result in enclosure ID 
       conflict error with the storage expansion enclosure or DS4000 storage 
       subsystem intentionally set the ID to 0.  
    
       The DS4200 and DS4700 storage subsystems and the EXP420 and EXP810 
       storage expansion enclosures did not have mechanical ID switches. Thus, 
       they are not susceptible to this problem. In addition, these storage 
       subsystems and storage expansion enclosures automatically set the 
       Enclosure IDs. IBM recommendation is not make any changes to these 
       settings unless the automatic enclosure ID settings resulting in non-
       unique single digit settings for enclosures (including the storage 
       subsystems with internal drive slots) in a given drive loop/channel.
        
         
    9. The ideal configuration for SATA drives is one drive in each EXP per 
       array, one logical drive per array and one OS disk partition per 
       logical drive. This configuration minimizes the random head movements 
       that increase stress on the SATA drives. As the number of drive 
       locations to which the heads have to move increases, application 
       performance and drive reliability may be impacted. If more logical 
       drives are configured, but not all of them used simultaneously, some 
       of the randomness can be avoided. SATA drives are best used for long 
       sequential reads and writes.
    
    10. IBM recommends at least one hot spare per EXP100 drive expansion enclosure.
        A total of 15 hot-spares can be defined per DS4000 storage subsystem 
        configuration.
       
    11. Starting with the DS4000 Storage Manager (SM) host software version 9.12 or
        later, the Storage Manager client script window looks for the files with 
        the file type of  ".script" as the possible script command files. In the 
        previous versions of the DS4000 Storage Manager host software, the script 
        window looks for the file type ".scr" instead. (i.e. enableAVT.script for 
        SM 9.12 or later vs. enableAVT.scr for pre-SM 9.12)
    
    12. When you configure a LUN from the DS4000 storage subsystem as a boot 
        device, the system displays a blue screen and does not respond when it 
        is manually or automatically set to hibernate. If you use a LUN in the 
        DS4000 storage subsystem as a boot device for Windows Server 2003, you 
        cannot enable the hibernation feature. To ensure that the hibernation 
        feature is disabled, complete the following steps:
    
        a. Select Start >> Settings >> Control Panel >> Power Options.
        b. Select the Hibernate tab.
      
        IMPORTANT: If the Hibernate tab does not appear in this dialog, then 
        your system does not support hibernate. No additional action is 
        required.
        
        c. Is the Enable Hibernate Support check box selected?
          | Yes – Unselect the check box, select Apply, and then go to step d.
          | No – Go to step d.
        d. Select the Power Schemes tab.
        e. From the Turn Off Hard Disks drop-down menu, select Never.
        f. Select OK.
    
    13. (Windows Server 2003) Cluster resources might fail on a host after 
        rebooting if the "Failback immediately" option is checked in the 
        Microsoft Cluster Server software. With this option checked, you might 
        see failed resources or devices not associated with their preferred 
        node. The current workaround is to make sure that the "Prevent 
        failback" option is checked under Group Properties. This is the default 
        option. Do not use the "Failback immediately" option.
    
    14. (Windows 2000) In a Microsoft Cluster Server (MSCS) environment 
        configured with VERITAS DMP, rebooting a server node owning the 
        resources might take a long time (10 to 15 minutes). It is possible 
        that the long server boot time might cause some Windows delayed write 
        failures. The workaround is to move all the resources from the server 
        node you are planning to reboot to another node before rebooting. 
    
    15. (Windows Server 2003) When in a server cluster environment, a failed 
        disk in the storage subsystem does not show as failed in the Cluster 
        Administrator. The host still receives I/O errors, and the disk is 
        shown as failed in the storage management software.
       
        This is a known issue with the Windows Server 2003 operating system.
        Choose one of the following workarounds:
        • Workaround 1 – Reboot the host that owns the disk resource. The 
          Cluster Administrator should now show the proper state of the disk 
          resource.
        • Workaround 2 – Change the ownership of the disk resource to a 
          different node in the server cluster configuration.
    
    
    =======================================================================
    
    3.0 Configuration Information
    -----------------------------
    
            
    3.1 Configuration Settings
    --------------------------
    
    
    1. For the Microsoft Windows servers in MSCS configuration, the IBM DS4000 
       FC2, FC2-133 single or dual port and FC 4Gbps single or dual port FC HBA 
       adapter "Port Down Retry Count" BIOS parameter must be change to 70 from 
       the default of 30. You can either use the Qlogic SANsurfer (aka. FAStT 
       Management Suite Java (FAStT MSJ)) program or the FC HBA Fast!UTIL 
       program to change the setting in 32bit or X64 64bit servers. To invoke 
       the Fast!UTIL program, perform the following steps:
       
       1. Reboot the server
       2. Press <CNTL+Q> when the statement "Press <CNTL+Q> for Fast!UTIL " is
          displayed when the server scan the FC-133 adapter during boot to get 
          invoke the Fast!UTIL program. 
       3. If there are multiple FC2-133 HBAs in your server, a list of the
          HBAs will be displayed. Select the appropriate HBA and press enter to 
          get to the Fast!Util Options menu. Then, select the Configuration 
          Settings menu option followed by Advanced Adapter Settings menu 
          option to display the menu that the Port Down Retry Count parameter 
          is displayed. Select the parameter and press enter to edit the new 
          value. 
       4. Press ESC twice to get to the "Save setting" menu. Select appropriate
          option to save the settings and return to the Fast!UTIL Options menu.
          You can either select another HBA for modification or press ESC and
          select Reboot System when you are prompted. 
       
       Alternatively, you can also use the Qlogic SANsurfer program to modify 
       the setting from the Microsoft Windows operating system environment. 
       This is also the recommended method to change NVSRAM setting in Intel 
       Itanium II 64bit (IA64) servers. However, you must reboot the servers 
       for the changes to become effective.
       
       In addition, the 
       HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Services\Disk registry value 
       must be increased to 120 from the default setting of 60. A utility, 
       SMRegUpdate.reg, is provided in the SMUtil host software package to 
       facilitate this registry change.
    
       The QLogic SANsurfer program can be downloaded from the DS4000 System 
       Storage support web site.
       
    2. If a host in a cluster server configuration lost a physical path to a 
       DS4000 storage subsystem controller, the logical drives that are mapped 
       to the cluster group will periodically failover and then failback 
       between cluster nodes until the failed path is restored. This behavior 
       is the result of the automatic logical drive failback feature of the 
       RDAC multipath driver. The cluster node with a failed path to a DS4000 
       controller will issue a failover command of all logical drives that were 
       mapped to the cluster group to the controller that it can access. After 
       a programmed interval, the nodes that did not have failed path will 
       issue failback command for the logical drives because they can access 
       the logical drives both controllers, resulting in the cluster node with 
       the failed path not be able to access certain logical drives. This 
       cluster node will then issue a failover command for all logical drives, 
       repeating the logical drives failover-failback cycle.   
       
       The workaround is to disable this automatic failback feature. For Windows,
       change the DisableLunRebalance registry setting of the 
       [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Services\rdacdisk\Parameters]
       registry key from 0 to 3 in each cluster node. Then, reboot each node 
       for the changes to take effect.
    
    3. By default, the IBM DS4000 Storage Manager 8.3 and higher firmware does 
       not automatically map logical drives when the IBM DS4000 storage 
       partitioning premium feature is enabled. This means that the logical 
       drives after being created are not automatically presented to the host
       systems.
       
       a. For a new installation, after creating new arrays and logical drives,
          create a storage partition with the host type of Windows 2000/Server 
          2003 non-clustered or Windows 2000/Server 2003 clustered and map the 
          logical drives to this partition. 
       
       b. If you are upgrading the NVSRAM with Storage Partitions, you may have
          to change the default host type to match the host system OS. After 
          upgrading the NVSRAM, the default host type is reset to Windows 
          2000/Server 2003 non-clustered for DS4000 storage subsystem with 
          controller firmware version 06.14.xx.xx or later. For DS4000 storage 
          server with controller firmware version 06.12.xx.xx or earlier, it is 
          reset to Windows non-clustered (SP5 or higher), instead.
                  
       Refer to the IBM DS4000 Storage Manager online help to learn more about 
       creating storage partitions and changing host types.
    
    
    4. Running script files for specific configurations. Apply the 
       appropriate scripts  to your subsystem based on the instructions you have 
       read in the publications or any instructions in the operating system 
       readme file. A description of each script is shown below.
    
       - SameWWN.script: Setup RAID controllers to have the same World Wide 
         Names. The World Wide Names (node) will be the same for each 
         controller pair. The NVSRAM default sets the RAID controllers
         to have the same World Wide Names.
    
       - DifferentWWN.script:  Setup RAID controllers to have different World 
         Wide Names. The World Wide Names (node) will be different for each 
         controller pair. The NVSRAM default sets the RAID controllers 
         to have the same World Wide Names.
    
       - EnableAVT_W2K_S2003_noncluster.script:  The script will enable automatic
         logical drive transfer (AVT/ADT) for the Windows 2000/Server 2003 
         non- cluster heterogenous host region. The default setting is to 
         disable AVT for this heterogenous host region. This setting is one 
         of the requirements for setting up the remote boot or SAN-boot. Do 
         not use this script unless it is specifically mentioned in the 
         applicable instructions. (This script can be used for other host 
         type if modifications are made in the script, replacing the Windows 
         2000/Server 2003 non-cluster host type with the appropriate host 
         type that needs to have AVT/ADT enabled) 
      
       - DisableAVT_W2K_S2003_noncluster.script:  The script will disable the 
         automatic logical drive transfer (AVT) for the Windows 2000/Server 
         2003 non-cluster heterogenous host region. This script will reset 
         the Windows 2000/Server 2003 non-cluster AVT setting to the default. 
         (This script can be used for other host type if modifications are 
         made in the script, replacing the Windows 2000/Server 2003 non-
         cluster host type with the appropriate host type that needs to have 
         AVT/ADT disabled) 
      
    6. When you are configuring IBM machine type 1722, 1724, 1742, 1814, 1815
       or 3552 storage subsystems in host cluster Remote Mirror configurations, 
       contact IBM support for supported host cluster configurations and 
       instructions for configuring IBM storage controllers in clustered Remote 
       Mirror configurations. 
    
    
    =======================================================================
    
    3.2 Hardware status and information
    -----------------------------------
    
     IBM Fibre Channel Host Bus Adapter
     ----------------------------------
     
       New installations for IBM Machine types 1722, 1724, 1742, 1814, 1815, 
       1818, 3552, and 3542 (DS4100, DS4200, DS4300, DS4400, DS4500, DS4700, 
       DS4800, DS5100, DS5300, FAStT500 and FAstT200) should be installed with 
       either the IBM DS4000 FC2-133, and FC4Gb PCIx single/dual port Host Bus 
       Adapter (39M5894/39M5895), and QLogic 4Gb FC Single/Dual-Port PCIe for 
       IBM System X (39R6525/39R6527),Emulex 4Gb FC PCIx Host Bus Adapter for 
       IBM System X (42D0405/42D0407) and Emulex 4Gb FC PCIe Host Bus Adapter 
       for IBM System X (42C2069/42C2071) Fibre Channel HBAs. The supported 
       BIOS and device driver for each type of Fibre Channel HBA by DS4000 
       storage subsystem models are listed below:
       
        --------------------------------------------------------------------
       |   DS4000     | FC-2           | FC2-133 single  | FC 4Gbps PCIx e  |
       |  Storage     | Device Driver  | & dual port     | single&dual port,|
       |  Subsystem   |                | Device Driver   |QLogic FC 4Gb PCIe|
       | (controller  |                |                 | Single/Dual-Port |
       |  fw vers.)   |                |                 |  Device Driver   |
        --------------------------------------------------------------------
       |  DS5300      |                |                 |                  |
       | (7.30.xx.xx) | 9.1.7.16  STOR | 9.1.7.16  STOR  | 9.1.7.16 STOR    |
        --------------------------------------------------------------------        
       |  DS5100      |                |                 |                  |
       | (7.30.xx.xx) | 9.1.7.16  STOR | 9.1.7.16  STOR  | 9.1.7.16 STOR    |
        --------------------------------------------------------------------    
       |  DS4800      | 9.1.4.10  SCSI | 9.1.4.10 SCSI   | 9.1.4.10 SCSI    |
       | (7.15.xx.xx) | 9.1.7.16  STOR | 9.1.7.16  STOR  | 9.1.7.16 STOR    |
        --------------------------------------------------------------------
       |  DS4700      | 9.1.4.10  SCSI | 9.1.4.10 SCSI   | 9.1.4.10 SCSI    |
       | (7.15.xx.xx) | 9.1.7.16  STOR | 9.1.7.16 STOR   | 9.1.7.16 STOR    |
        --------------------------------------------------------------------
       |  DS4500      | 9.1.4.10  SCSI | 9.1.4.10 SCSI   | 9.1.4.10 SCSI    |
       | (6.60.xx.xx) | 9.1.7.16  STOR | 9.1.7.16 STOR   | 9.1.7.16 STOR    |
        --------------------------------------------------------------------
       |  DS4400      | 9.1.4.10  SCSI | 9.1.4.10 SCSI   | 9.1.4.10 SCSI    |
       | (6.12.56.xx) | 9.1.7.16  STOR | 9.1.7.16 STOR   | 9.1.7.16 STOR    |
       --------------------------------------------------------------------
       |  DS4300 Turbo| 9.1.4.10  SCSI | 9.1.4.10 SCSI   | 9.1.4.10 SCSI    |
       | (6.60.xx.xx) | 9.1.7.16  STOR | 9.1.7.16 STOR   | 9.1.7.16 STOR    |
        --------------------------------------------------------------------
       |  DS4300 Dual | 9.1.4.10  SCSI | 9.1.4.10 SCSI   | 9.1.4.10 SCSI    |
       | (6.60.xx.xx) | 9.1.7.16  STOR | 9.1.7.16 STOR   | 9.1.7.16 STOR    |
        --------------------------------------------------------------------
       |  DS4200      | 9.1.4.10  SCSI | 9.1.4.10 SCSI   | 9.1.4.10 SCSI    |
       | (7.10.xx.xx) | 9.1.7.16  STOR | 9.1.7.16 STOR   | 9.1.7.16 STOR    |
        --------------------------------------------------------------------
       |  DS4100      | 9.1.4.10  SCSI | 9.1.4.10 SCSI   | 9.1.4.10 SCSI    |
       | (6.12.56.xx) | 9.1.7.16  STOR | 9.1.7.16 STOR   | 9.1.7.16 STOR    |
       --------------------------------------------------------------------
       Support device driver versions for each type of FC HBA by DS4000/DS5000
       storage subsystem model
       Note: "SCSI" and "STOR" are used to indicate the Microsoft miniport 
             model that the device driver is based on. The Microsoft Windows 
             Server 2003 - X64 edition operating system supports only device 
             drivers based on STORport miniport device driver model.  
     
     
        --------------------------------------------------------------------
       |   DS4000    | FC-2            | FC2-133 single  | FC 4Gbps PCIx    |
       |  Storage    |                 | & dual port     | single&dual port |
       |  Subsystem  |                 |                 |QLogic FC 4Gb PCIe|
       |             |                 |                 |Single/Dual-Port  |
       | --------------------------------------------------------------------
       |  DS5300     | BIOS  1.54      | BIOS  1.54      | BIOS  1.29       |
       |             |                 | EFI driver 1.50 | EFI driver 1.09  |
        --------------------------------------------------------------------
       |  DS5100     | BIOS  1.54      | BIOS  1.54      | BIOS  1.29       |
       |             |                 | EFI driver 1.50 | EFI driver 1.09  |
        --------------------------------------------------------------------   
       |  DS4800     | BIOS  1.54      | BIOS  1.54      | BIOS  1.29       |
       |             |                 | EFI driver 1.50 | EFI driver 1.09  |
        --------------------------------------------------------------------
       |  DS4700     | BIOS  1.54      | BIOS  1.54      | BIOS  1.29       |
       |             |                 | EFI driver 1.50 | EFI driver 1.09  |
        --------------------------------------------------------------------
       |  DS4500     | BIOS  1.54      | BIOS  1.54      | BIOS  1.29       |
       |             |                 | EFI driver 1.50 | EFI driver 1.09  |
        --------------------------------------------------------------------
       |  DS4400     | BIOS  1.54      | BIOS  1.54      | BIOS  1.29       |
       |             |                 | EFI driver 1.50 | EFI driver 1.09  |
       --------------------------------------------------------------------
       |  DS4300     | BIOS  1.54      | BIOS  1.54      | BIOS  1.29       |
       |             |                 | EFI driver 1.50 | EFI driver 1.09  |
        --------------------------------------------------------------------
       |  DS4200     | BIOS  1.54      | BIOS  1.54      | BIOS  1.29       |
       |             |                 | EFI driver 1.50 | EFI driver 1.09  |
        --------------------------------------------------------------------
       |  DS4100     | BIOS  1.54      | BIOS  1.54      | BIOS  1.29       |
       |             |                 | EFI driver 1.50 | EFI driver 1.09  |
       -------------------------------------------------------------------- 
       Support BIOS(EFI driver) version for each type of FC HBA by DS4000/DS5000 
       storage subsystem model 
    
    
       For more information on the latest support FC HBA device driver and BIOS 
       (or EFI driver), refer to the IBM Support Web site.    
    
    
      Emulex Fibre Channel Host Bus Adapter
     -------------------------------------
        --------------------------------------------------------------------
       |   DS4000     | LP90XX         | LP1000x         | LP1100x          |
       |  Storage     | Device Driver  | Device Driver   |Emulex 4Gb FC PCIx|
       |  Subsystem   |                |                 |Emulex 4Gb FC PCIe|
       | (controller  |                |                 |for IBM System X  |
       |  fw vers.)   |                |                 | Device Driver    |
        --------------------------------------------------------------------
       |  DS5300      |                |                 |                  |
       | (7.30.xx.xx) |   2.01A4  STOR |   2.01A4 STOR   |   2.01A4 STOR    |
        --------------------------------------------------------------------        
       |  DS5100      |                |                 |                  |
       | (7.30.xx.xx) |   2.01A4  STOR |   2.01A4 STOR   |   2.01A4 STOR    |
        --------------------------------------------------------------------    
       |  DS4800      |   5.30A2  SCSI |   5.30A2 SCSI   |   5.30A2 SCSI    |
       | (7.15.xx.xx) |   2.01A4  STOR |   2.01A4 STOR   |   2.01A4 STOR    |
        --------------------------------------------------------------------
       |  DS4700      |   5.30A2  SCSI |   5.30A2 SCSI   |   5.30A2 SCSI    |
       | (7.15.xx.xx) |   2.01A4  STOR |   2.01A4 STOR   |   2.01A4 STOR    |
        --------------------------------------------------------------------
       |  DS4500      |   5.30A2  SCSI |   5.30A2 SCSI   |   5.30A2 SCSI    |
       | (6.60.xx.xx) |   2.01A4  STOR |   2.01A4 STOR   |   2.01A4 STOR    |
        --------------------------------------------------------------------
       |  DS4400      |   5.30A2  SCSI |   5.30A2 SCSI   |   5.30A2 SCSI    |
       | (6.12.56.xx) |   2.01A4  STOR |   2.01A4 STOR   |   2.01A4 STOR    |
       ---------------------------------------------------------------------
       |  DS4300 Turbo|   5.30A2  SCSI |   5.30A2 SCSI   |   5.30A2 SCSI    |
       | (6.60.xx.xx) |   2.01A4  STOR |   2.01A4 STOR   |   2.01A4 STOR    |
        -------------------------------------------------------------------
       |  DS4300 Dual |   5.30A2  SCSI |   5.30A2 SCSI   |   5.30A2 SCSI    |
       | (6.60.xx.xx) |   2.01A4  STOR |   2.01A4 STOR   |   2.01A4 STOR    |
        --------------------------------------------------------------------
       |  DS4200      |   5.30A2  SCSI |   5.30A2 SCSI   |   5.30A2 SCSI    |
       | (7.10.xx.xx) |   2.01A4  STOR |   2.01A4 STOR   |   2.01A4 STOR    |
        --------------------------------------------------------------------
       |  DS4100      |   5.30A2  SCSI |   5.30A2 SCSI   |   5.30A2 SCSI    |
       | (6.12.56.xx) |   2.01A4  STOR |   2.01A4 STOR   |   2.01A4 STOR    |
       --------------------------------------------------------------------
    
     
    =======================================================================
    
    3.3 Unsupported configurations
    ------------------------------
    
       The following lists configurations that are currently not being 
       supported with IBM DS Storage Manager Version 10.30.
    
    
       1. The DS4100 (machine type 1724-all models) storage subsystem does not
          support the attachment of the DS4000 EXP710, EXP700 and EXP500 (FC) 
          drive expansion enclosure. Please contact IBM representatives or 
          resellers for the availability of such support in the future.
       
       2. The DS4800 storage subsystem (machine type 1815-all models) does not
          support the attachment of the FAStT EXP500 and DS4000 EXP700 drive 
          expansion enclosures. 
    
       3. The DS4200 (machine type 1814 - models 7VA/H) with controller firmware
          6.16.88.xx installed does not support the attachment of the DS4000 
          EXP100 (SATA), EXP710 (FC) and EXP810 (SATA and FC) drive expansion 
          enclosures. In addition, it does not support Fibre Channel disk drive 
          options.   
    
       4. The IBM DS4000 EXP420 Expansion Enclosure is not supported attached 
          to any other IBM DS4000 Storage Controllers except the DS4200.
          
       5. The DS4100 with Single Controller option does not support the 
          attachment of the DS4000 storage expansion enclosures.
          
       6. The DS4300 storage subsystem with Single Controller option does not
          support the controller firmware version 06.1x.xx.xx. The correct 
          firmware version for these DS4300 storage subsystem models is 
          05.34.xx.xx.
          
       7. Fibre Channel loop environments with the IBM Fibre Channel Hub, 
          machine type 3523 and 3534, in conjunction with the IBM Fibre Channel 
          Switch, machine types 2109-S16, 2109-F16 or 2109-S8. In this 
          configuration, the hub is connected between the switch and the IBM 
          Fibre Channel RAID Controllers.
    
       8. The IBM Fibre Channel hub, machine type 3523, connected to IBM 
          machine type 1722, 1724, 1742, 1814, 1815, 3542 and 3552.
    
       9. A configuration in which a server with only one FC host bus 
          adapter connects directly to any DS4000 storage subsystem with dual 
          controllers is not supported. The supported configuration is the 
          one in which the server with only one FC host bus adapter connects 
          to both controller ports of any DS4000 storage subsystem with dual 
          controllers via Fibre Channel (FC) switch (SAN-attached 
          configuration.)
          
      10. The DS5300 and DS5100 storage subsystem (machine type 1818-all models) 
          does not support the attachment of the FAStT EXP500, DS4000 EXP700, 
          DS4000 EXP710, DS4000 EXP100, or DS4000 EXP420 drive expansion 
          enclosures. 
          
      11. The IBM DS5000 EXP5000 Expansion Enclosure is not supported attached 
          to any other IBM Storage Controllers except the DS5300 and DS5100.              
    
          
    =======================================================================
    
    4.0   Unattended Mode
    -------------------------------
            N/A
    
    =======================================================================
    
    5.0   WEB Sites and Support Phone Number
    --------------------------------------------------------------
    
    5.1  IBM System Storage™ Disk Storage Systems Technical Support web site:
         http://www.ibm.com/servers/storage/support/disk/
    
    5.2  IBM System Storage™ Marketing Web Site:
         http://www.ibm.com/servers/storage/disk
    
    5.3  You can receive hardware service through IBM Services or through your 
         IBM reseller, if your reseller is authorized by IBM to provide warranty 
         service. See http://www.ibm.com/planetwide/ for support telephone 
         numbers, or in the U.S. and Canada, call 1-800-IBM-SERV (1-800-426-
         7378).
    
    
    
      IMPORTANT:
      You should download the latest version of the DS Storage Manager host 
      software, the DS4000/DS5000 storage subsystem controller firmware, the 
      DS4000/DS5000 drive expansion enclosure ESM firmware and the drive 
      firmware at the time of the initial installation and when product updates 
      become available. 
    
      For more information about how to register for support notifications, 
      see the following IBM Support Web page: 
    
        www.ibm.com/systems/support/storage/subscribe/moreinfo.html 
    
      You can also check the Stay Informed section of the IBM Disk Support 
      Web site, at the following address: 
    
        www.ibm.com/systems/support/storage/disk
    
     
    =======================================================================
    
    6.0 Trademarks and Notices
    --------------------------
    
         The following terms are trademarks of the IBM Corporation in the
         United States or other countries or both:
    
         IBM
         
         System Storage
         
         the e-business logo
    
         xSeries, pSeries
    
         HelpCenter
         
         UNIX is a registered of The Open Group in the United States and other 
         countries.
      
         Microsoft, Windows, and Windows NT are of Microsoft Corporation in the 
         United States, other countries, or both.
      
         Linux is a trademark of Linus Torvalds in the United States, other 
         countries, or both.
      
         Java and all Java-based trademarks and logos are trademarks of Sun 
         Microsystems, Inc. in the United States, other countries, or both.
        
         QLogic and SANsurfer are trademarks of QLogic Corporation.
      
         Other company, product, or service names may be trademarks
         or service marks of others.
    
    =======================================================================
    
    7.0 Disclaimer
    --------------
    
    7.1 THIS DOCUMENT IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY 
        KIND. IBM DISCLAIMS ALL WARRANTIES, WHETHER EXPRESS OR IMPLIED, 
        INCLUDING WITHOUT LIMITATION, THE IMPLIED WARRANTIES OF FITNESS 
        FOR A PARTICULAR PURPOSE AND MERCHANTABILITY WITH RESPECT TO THE 
        INFORMATION IN THIS DOCUMENT. BY FURNISHING THIS DOCUMENT, IBM 
        GRANTS NO LICENSES TO ANY PATENTS OR COPYRIGHTS.
    
    
    7.2 Note to U.S. Government Users -- Documentation related to
        restricted rights -- Use, duplication or disclosure is subject 
        to restrictions set forth in GSA ADP Schedule Contract with IBM 
        Corporation.
    
    
    


     

     

    IBM ServeRAID Application CD v9.30-17006 - IBM System x and BladeCenter

     

     

    ServeRAID Manager 9.30 (17006)

    Problem(s) Fixed:

    • Added fix for false drive state - Drive state is shown as rebuilding in SRM/ARCONF even when no rebuilding is in progress.
    • Added fix for Logical drive rename issue - Unable to assign logical drive name with a space character. o Added fix for RAID-6 degraded event notification in SRM.
    • Fix added for false hotspare - During Raid array creation using SAS hardrives, array shown as protected by SATA global hotspare.

     

    Supported systems

     

    IBM 서버 가이드를 가지고 설치를 하다보명 아래와 같이 드라이버는 설치가 되었는데 Raid 정보를 볼수 있는 프로그램(MSM)

    같은 프로그램이 설치가 안된다.

    .

     

     

    Supported controllers:

    • Onboard LSI 1064 SAS controller
    • Onboard LSI 1064e SAS controller
    • Onboard LSI 1068e SAS controller
    • Onboard LSI 1078 SAS controller
    • IBM SAS HBA (25R8060)
    • IBM 3Gb SAS HBA v2 (44E8700)
    • IBM SAS Expansion Card (CFFv) for IBM BladeCenter (39Y9190)
    • IBM SAS Connectivity Card (CFFv) for IBM BladeCenter (43W3974)
    • IBM SAS/SATA RAID Kit (42C1312, 42C1313)
    • IBM ServeRAID BR10i SAS controller (44E8688)
    • IBM ServeRAID BR10il SAS controller (44X0411)
    • IBM ServeRAID BR10il v2 SAS controller (49Y4731)
    • ServeRAID M5025 SAS/SATA controller (46M0830)
    • ServeRAID M5016 SAS/SATA Controller for IBM System x (90Y4304)
    • ServeRAID M5015 SAS/SATA controller (46M0829)
    • ServeRAID M5014 SAS/SATA controller (46M0916)
    • ServeRAID M1015 SAS/SATA Controller (46M0831)
    • IBM ServeRAID MR10il SAS controller (44E8767)
    • IBM ServeRAID MR10is SAS controller (44E8695)
    • IBM ServeRAID MR10ie (CIOv) SAS controller (46C7167)
    • IBM ServeRAID MR10i SAS controller (43W4296)
    • IBM ServeRAID MR10k SAS controller (43W4280)
    • IBM ServeRAID MR10M SAS controller (43W4339)
    • MegaRAID 8480 SAS controller (39R8850)

    Change history

    NOTE TO SERVICE - Reference RETAIN #N/A

    11.08.03.00 - Suggested

    Enhancements

    • Support for ServeRAID M5016
    • Support for Windows 2008 R2 SP1
    • Improved Dashboard for advanced software options Fixes
    • Fixed issue where MSM Does Not Correctly Install Visual C++ Libraries during Unattended Install mode.
    • Fixed issue where MSM Unattended Install mode will only install Standalone setup even when another setup option is chosen.
    • Fixed issue where MSM was sending SMTP breaches incorrectly.